Triggers, sound and sleep mode

Hello!

Ask me any question about Lympik.

Please be as specific as possible so I can help you better.

Answers are AI-generated and may be inaccurate!

All settings in this lesson are in the Config section of the Advanced page. Tap Save configuration after changing them; they take effect when the box restarts.

Trigger

  • Delay (default 0 ms): the sound starts right after the trigger.
  • Dead time (default 3000 ms): triggers within 3 seconds of the last play are ignored. This applies to all sources.
  • Sources: tick the inputs that may start a sound: Wired 1 (external contact or sensor), Wired 2 (speed) (external sensor) and Vibration (IMU) (the built-in vibration sensor).
Trigger settings with delay, dead time and the three sources Wired 1, Wired 2 (speed) and Vibration (IMU)

All three sources are on by default. If you untick all of them, the box switches all three back on, so it can never end up silent. The vibration trigger also has its own hold time, see Vibration trigger: mounting and tuning.

Sound

  • Volume (default 80): 40 is practically silent, 100 is the maximum. The steps aren't linear: 80 is clearly quieter than 100, and below about 60 it is very quiet.
  • Play order (default Random): Random or Sequentially (in the order of the file list).

Light

  • Count (default 1): how many times the light flashes per trigger. 0 switches the light off.
  • Length (default 100 ms): how long each flash lasts.

Sleep mode

During the nightly sleep window the box ignores all triggers.

  • Sleep at (UTC), default 16: the hour the sleep window starts, in UTC.
  • Sleep length (h), default 15: how many hours it lasts. 0 switches sleep mode off.

With the defaults, the box is active from 08:00 to 17:00 Central European winter time (CET).

Caution: sleep times are set in UTC. Subtract 1 hour from your local time in winter (CET) and 2 hours in summer (CEST). Example: to start sleep mode at 18:00 CET, enter 17.